TF
TinnerFlow
Menu
Fix a Problem
Install Guides
Check My Work
Ask Clearly
Field Library
Home
/
Categories
Joints, TDC, Flanges & Connections
244 records, red lane first.
Stop
Ductwork in Healthcare Facilities
Foreman script · 3rd Year
Stop
How do you avoid cracking a VAV reheat coil connection when tightening piping?
Apprentice question · 3rd Year
Stop
How do you properly bend and install a slip and drive (S&D) connection?
Apprentice question · 1st Year
Stop
Not cutting flex to proper length before connecting
Foreman script · 3rd Year
Stop
Not pressure-testing a custom grease duct assembly before installation per NFPA 96
Common mistake · 4th Year
Stop
Outer jacket/vapor barrier cut and not repaired
Foreman script · 3rd Year
Stop
Outside Air Intake Clearance From Exhaust
Field problem · 4th Year
Stop
Outside Air Intake Clearance From Exhaust
Foreman script · 3rd Year
Stop
Pressure Class vs Gauge Selection
Field problem · 4th Year
Stop
Rectangular Duct Reinforcement
Field problem · 4th Year
Stop
Underestimating the weight of a large duct assembly before rigging it overhead
Common mistake · 4th Year
Stop
What if structural bracing blocks a VAV access panel?
Apprentice question · 3rd Year
Check first
Actuator Mounting on Dampers
Field problem · 2nd Year
Check first
Actuator Mounting on Dampers
Foreman script · 2nd Year
Check first
Airflow direction/damper position before flex not checked
Field problem · 2nd Year
Check first
Backside Riser Flange Hardware Cannot Be Reached
Foreman script · 2nd Year
Check first
Before RTU sets on curb - what do I check?
Field problem · 2nd Year
Check first
Before fastening duct to equipment cabinet
Field problem · 2nd Year
Check first
Bending flex tighter than it wants to bend
Field problem · 2nd Year
Check first
Bending flex tighter than it wants to bend
Foreman script · 3rd Year
Check first
Bird Screen on Outside Air Intakes
Field problem · 2nd Year
Check first
Boot/register not aligned with ceiling tile
Field problem · 2nd Year
Check first
Boot/register not aligned with ceiling tile
Foreman script · 3rd Year
Check first
Canvas connector tears on startup
Apprentice question · 3rd Year
Check first
Collar before insulation jacket not sealed
Field problem · 2nd Year
Check first
Condensate Drain Slope and Trap
Field problem · 2nd Year
Check first
Condensate Drain Slope and Trap
Foreman script · 2nd Year
Check first
Covering bad flex route because it is above ceiling
Field problem · 2nd Year
Check first
Covering bad flex route because it is above ceiling
Foreman script · 3rd Year
Check first
Diffuser end after ceiling tile installed not checked
Field problem · 2nd Year
Check first
Do I put the butyl gasket tape on the inside or outside of the bolt holes on a TDC flange?
Apprentice question · 1st Year
Check first
Drywall or framing crushes a flex duct run
Field problem · 2nd Year
Check first
Ductwork Gauge Markings
Field problem · 2nd Year
Check first
Ductwork in Assembly and Convention Spaces
Foreman script · 3rd Year
Check first
Ductwork in Gyms and Fitness Centers
Foreman script · 2nd Year
Check first
Ductwork in Hotels and Hospitality
Foreman script · 2nd Year
Check first
Ductwork in Telecommunications Rooms
Foreman script · 2nd Year
Check first
Ductwork in Theaters and Performance Spaces
Foreman script · 3rd Year
Check first
Equipment is landing on curb and something looks wrong
Field problem · 2nd Year
Check first
Excess flex length stuffed above ceiling
Field problem · 2nd Year
Check first
Excess flex length stuffed above ceiling
Foreman script · 3rd Year
Check first
Exhaust Discharge Orientation
Field problem · 2nd Year
Check first
Exhaust Discharge Orientation
Foreman script · 2nd Year
Check first
Exhaust Fan Backdraft Damper
Field problem · 2nd Year
Check first
Exhaust Fan Backdraft Damper
Foreman script · 2nd Year
Check first
Fan Inlet And Outlet Transition
Field problem · 2nd Year
Check first
Fan Inlet And Outlet Transition
Foreman script · 3rd Year
Check first
Flex collar blocked by ceiling grid or framing
Foreman script · 3rd Year
Check first
Flex crushed by other trade after install
Foreman script · 3rd Year
Check first
Flex inner liner not pulled over collar fully
Field problem · 2nd Year
Check first
Flex inner liner not pulled over collar fully
Foreman script · 3rd Year
Check first
Flex kinked around framing or pipe
Field problem · 2nd Year
Check first
Flex kinked around framing or pipe
Foreman script · 3rd Year
Check first
Flex lying on sharp metal edge
Field problem · 2nd Year
Check first
Flex lying on sharp metal edge
Foreman script · 3rd Year
Check first
Flex run too long for intended use
Field problem · 2nd Year
Check first
Flex run too long for intended use
Foreman script · 3rd Year
Check first
Flex sagging between supports
Field problem · 2nd Year
Check first
Flex sagging between supports
Foreman script · 3rd Year
Check first
Flex twisted and airflow restricted
Field problem · 2nd Year
Check first
Flex twisted and airflow restricted
Foreman script · 3rd Year
Check first
Flexible Connector At Fan
Field problem · 2nd Year
Check first
Flexible Connector At Fan
Foreman script · 2nd Year
Check first
How do I close a blind S-cleat joint in a tight chase when I can't reach the back?
Apprentice question · 2nd Year
Check first
How do I fix a piece of rectangular duct if it's knocked together out of square?
Apprentice question · 1st Year
Check first
How do I install TDC/TDF corners without smashing them or bending the flange?
Apprentice question · 1st Year
Check first
How do I tell the difference between a Pittsburgh seam and a snap-lock seam?
Apprentice question · 1st Year
Check first
How far apart should the cleats be on a TDC/TDF transverse joint?
Apprentice question · 1st Year
Check first
Inner liner pulled loose after diffuser is moved
Field problem · 2nd Year
Check first
Inner liner pulled loose after diffuser is moved
Foreman script · 3rd Year
Check first
Inner liner torn during install
Field problem · 2nd Year
Check first
Inner liner torn during install
Foreman script · 3rd Year
Check first
Installing a flex duct connection that is kinked at the elbow
Common mistake · 2nd Year
Check first
Internal Tie Rods
Field problem · 2nd Year
Check first
Louver Free Area vs Face Area
Field problem · 2nd Year
Check first
Mixed insulated/uninsulated flex incorrectly
Field problem · 2nd Year
Check first
Mixing insulated/uninsulated flex incorrectly
Foreman script · 3rd Year
Check first
Not checking airflow direction/damper position before f
Foreman script · 4th Year
Check first
Not checking diffuser end after ceiling tile installed
Foreman script · 3rd Year
Check first
Not cutting flex to proper length before connecting
Field problem · 2nd Year
Check first
Not field-verifying that pre-punched TDC duct flanges align before ordering an entire duct package
Common mistake · 2nd Year
Check first
Not giving straight section off collar before bend
Field problem · 2nd Year
Check first
Not giving straight section off collar before bend
Foreman script · 3rd Year
Check first
Not pressing TDC (transverse duct connector) flanges down flush before assembly
Common mistake · 2nd Year
Check first
Not sealing collar before insulation jacket
Foreman script · 3rd Year
Check first
Not supporting flex at both ends
Field problem · 2nd Year
Check first
Not supporting flex at both ends
Foreman script · 3rd Year
Check first
Not supporting flex near bend
Field problem · 2nd Year
Check first
Not supporting flex near bend
Foreman script · 3rd Year
Check first
Outer jacket/vapor barrier cut and not repaired
Field problem · 2nd Year
Check first
Pool or natatorium equipment exposed to corrosive air
Field problem · 2nd Year
Check first
Reading Duct Gauge Off The Spec
Field problem · 2nd Year
Check first
S-Cleat and Drive Slide Direction
Field problem · 2nd Year
Check first
Seal Class A/B/C
Field problem · 2nd Year
Check first
Support spacing too wide
Field problem · 2nd Year
Check first
Support spacing too wide
Foreman script · 3rd Year
Check first
TDC Corner Assembly
Field problem · 2nd Year
Check first
TDC/TDF Flanged Connections
Field problem · 2nd Year
Check first
TDF Flange Corner Gap
Field problem · 2nd Year
Check first
The shop sent the wrong fitting or elbow and the duct run is stopped
Field problem · 2nd Year
Check first
Transition from hard duct to flex not supported
Field problem · 2nd Year
Check first
Transition from hard duct to flex not supported
Foreman script · 3rd Year
Check first
Tying New Duct To Existing
Field problem · 2nd Year
Check first
Using flex to solve a bad layout instead of fixing hard
Foreman script · 3rd Year
Check first
Using flex to solve a bad layout instead of fixing hard duct
Field problem · 2nd Year
Check first
Using narrow strap that pinches flex
Field problem · 2nd Year
Check first
Using narrow strap that pinches flex
Foreman script · 3rd Year
Check first
Using tape alone as mechanical connection
Field problem · 2nd Year
Check first
Using tape alone as mechanical connection
Foreman script · 3rd Year
Check first
VAV Box Clearance Requirements
Foreman script · 2nd Year
Check first
VAV Box Inlet and Outlet Orientation
Foreman script · 2nd Year
Check first
Vibration Isolator Clearance
Field problem · 2nd Year
Check first
Vibration Isolator Clearance
Foreman script · 2nd Year
Check first
What Pressure Class Means
Field problem · 2nd Year
Check first
What's the proper way to cross-brake a piece of flat metal in the field?
Apprentice question · 1st Year
Check first
What's the trick to seating a stubborn Pittsburgh seam on a large rectangular fitting?
Apprentice question · 1st Year
Check first
Which way does the "drive" face on a vertical drop?
Apprentice question · 1st Year
Check first
Why does a shallow condensate trap make an AHU drain pan overflow?
Apprentice question · 3rd Year
Check first
Why is a hard elbow right at a VAV inlet a problem?
Apprentice question · 3rd Year
Check first
Why is it bad to neck down a VAV discharge immediately after the box?
Apprentice question · 3rd Year
Check first
Why is stretching butyl gasket tape a bad idea?
Apprentice question · 1st Year
Check first
Why would a flexible fan connector balloon out and rip loose?
Apprentice question · 3rd Year
Check first
Wrong flex diameter for branch
Field problem · 2nd Year
Check first
Wrong flex diameter for branch
Foreman script · 3rd Year
Check first
Zip tie/clamp on outer jacket instead of inner liner
Field problem · 2nd Year
Check first
Zip tie/clamp on outer jacket instead of inner liner
Foreman script · 3rd Year
Coordinate
BAS Handoff Documentation
Foreman script · 3rd Year
Coordinate
Flex collar blocked by ceiling grid or framing
Field problem · 3rd Year
Coordinate
Flex crushed by other trade after install
Field problem · 3rd Year
Standard
A flex duct clamp cuts the outer vapor jacket
Field problem · 1st Year
Standard
BAS Handoff Documentation
Field problem · 1st Year
Standard
Cross-Breaking And Beading
Field problem · 1st Year
Standard
Duct Offset Direction On Plan
Field problem · 1st Year
Standard
Ductwork in Restaurants (Non-Grease)
Foreman script · 2nd Year
Standard
Ductwork in Retail Spaces
Foreman script · 2nd Year
Standard
Flex duct is sagging and choking airflow
Field problem · 1st Year
Standard
Flex duct kinks at a register boot and needs a 45-degree hard fitting
Field problem · 1st Year
Standard
Flex duct kinks right off a plenum start collar
Field problem · 1st Year
Standard
How do I avoid the over-reamed pipe flange fracture?
Apprentice question · 1st Year
Standard
How do I fix a Pittsburgh seam that was not knocked down and is leaking?
Apprentice question · 1st Year
Standard
How do I fix a screaming TDC/Ductmate gasket leak?
Apprentice question · 2nd Year
Standard
How do I fix a stripped TDC or Ductmate corner bolt?
Apprentice question · 2nd Year
Standard
How do I fix a whistling TDC/Ductmate flange on a large duct?
Apprentice question · 2nd Year
Standard
How do you line up twisted companion flanges without damaging the duct?
Apprentice question · 2nd Year
Standard
Louver Screen And Bird Screen Access
Field problem · 1st Year
Standard
Louver Screen And Bird Screen Access
Foreman script · 2nd Year
Standard
Pittsburgh Lock Seam Direction
Field problem · 1st Year
Standard
Reading A Duct Size Callout
Field problem · 1st Year
Standard
Slip And Drive Joints
Field problem · 1st Year
Standard
What's the easiest way to line up massive ductwork pieces on a duct jack (Genie lift)?
Apprentice question · 1st Year
Standard
Why can a wide TDC or TDF joint leak in the center even when the corners are bolted?
Apprentice question · 2nd Year
Standard
Why do TDC flanges bind on a tight back-to-back 45-degree offset?
Apprentice question · 2nd Year
Standard
Why do large TDC/TDF joints need center flange clips?
Apprentice question · 1st Year
Standard
Why does a fan coil need a flexible connector at the duct connection?
Apprentice question · 2nd Year
Standard
Why does a metal-to-metal duct connection at a louver sleeve whistle?
Apprentice question · 2nd Year
Standard
Why does a short flange lip make an S-cleat joint fail?
Apprentice question · 1st Year
Reference
Acoustic sealant
Definition · 1st Year
Reference
Beam attachment
Definition · 1st Year
Reference
Beam clamp
Definition · 1st Year
Reference
Brazed joint
Definition · 1st Year
Reference
Button punch joint
Definition · 1st Year
Reference
Butyl sealant
Definition · 1st Year
Reference
Canvas connector
Definition · 1st Year
Reference
Closed-cell gasket
Definition · 1st Year
Reference
Closed-end rivet
Definition · 1st Year
Reference
Companion angle joint
Definition · 1st Year
Reference
Concrete insert
Definition · 1st Year
Reference
Concrete screw
Definition · 1st Year
Reference
Corner piece
Definition · 1st Year
Reference
Crimp and slip joint
Definition · 1st Year
Reference
Cross break joint
Definition · 1st Year
Reference
Draw band joint
Definition · 1st Year
Reference
Drive cleat joint
Definition · 1st Year
Reference
Drop-in anchor
Definition · 1st Year
Reference
Duct connector
Definition · 1st Year
Reference
Duct gasket
Definition · 1st Year
Reference
Duct joint sealer
Definition · 1st Year
Reference
Duct sealer
Definition · 1st Year
Reference
Duct tape
Definition · 1st Year
Reference
Ductmate
Definition · 1st Year
Reference
E-Z Flange
Definition · 1st Year
Reference
Firestop caulk
Definition · 1st Year
Reference
Flange bolt
Definition · 1st Year
Reference
Flange gasket
Definition · 1st Year
Reference
Flange nut
Definition · 1st Year
Reference
Flange sealant
Definition · 1st Year
Reference
Flange washer
Definition · 1st Year
Reference
Flanged connection
Definition · 1st Year
Reference
Flexible connector
Definition · 1st Year
Reference
Gasketed joint
Definition · 1st Year
Reference
Intumescent sealant
Definition · 1st Year
Reference
Joint clamp
Definition · 1st Year
Reference
Joint reinforcement
Definition · 1st Year
Reference
Lag screw
Definition · 1st Year
Reference
Large flange rivet
Definition · 1st Year
Reference
Latex caulk
Definition · 1st Year
Reference
Leak lock
Definition · 1st Year
Reference
Machine screw
Definition · 1st Year
Reference
Mastic
Definition · 1st Year
Reference
Material Staging Basics
Reference · 1st Year
Reference
Multi-grip rivet
Definition · 1st Year
Reference
Neoprene connector
Definition · 1st Year
Reference
Open-cell gasket
Definition · 1st Year
Reference
Pittsburgh and Snap-Lock Seams
Reference · 1st Year
Reference
Pittsburgh joint
Definition · 1st Year
Reference
Pittsburgh seam connection
Definition · 1st Year
Reference
Polyurethane sealant
Definition · 1st Year
Reference
Pop rivet
Definition · 1st Year
Reference
Post-installed anchor
Definition · 1st Year
Reference
Pressure-sensitive tape
Definition · 1st Year
Reference
Raw edge joint
Definition · 1st Year
Reference
Reinforcing tape
Definition · 1st Year
Reference
Rod coupling
Definition · 1st Year
Reference
Rod hanger
Definition · 1st Year
Reference
S-and-Drive Basics
Reference · 1st Year
Reference
S-cleat joint
Definition · 1st Year
Reference
Seam weld
Definition · 1st Year
Reference
Self-piercing screw
Definition · 1st Year
Reference
Sheet metal screw
Definition · 1st Year
Reference
Silicone sealant
Definition · 1st Year
Reference
Sleeve anchor
Definition · 1st Year
Reference
Slip and drive connection
Definition · 1st Year
Reference
Slip connection
Definition · 1st Year
Reference
Snap-lock joint
Definition · 1st Year
Reference
Soldered joint
Definition · 1st Year
Reference
Solvent-based mastic
Definition · 1st Year
Reference
Spot weld
Definition · 1st Year
Reference
Standing S joint
Definition · 1st Year
Reference
Standing seam connection
Definition · 1st Year
Reference
TDC
Definition · 1st Year
Reference
TDC/TDF/Ductmate Basics
Reference · 1st Year
Reference
Teflon tape
Definition · 1st Year
Reference
Tek screw
Definition · 1st Year
Reference
Threaded rod
Definition · 1st Year
Reference
Toggle bolt
Definition · 1st Year
Reference
Transverse duct connector
Definition · 1st Year
Reference
Transverse duct flange
Definition · 1st Year
Reference
UL 181 mastic
Definition · 1st Year
Reference
UL 181 tape
Definition · 1st Year
Reference
Vapor barrier tape
Definition · 1st Year
Reference
Water-based duct mastic
Definition · 1st Year
Reference
Wedge anchor
Definition · 1st Year
Reference
Welded connection
Definition · 1st Year
Reference
Zip screw
Definition · 1st Year