Per the International Mechanical Code (IMC Section 506), a standard, uninsulated Type 1 commercial kitchen grease duct must maintain a strict minimum of 18 inches of clearance to any combustible materials (like wood framing or drywall).
['Per the International Mechanical Code (IMC Section 506), a standard, uninsulated Type 1 commercial kitchen grease duct must maintain a strict minimum of 18 inches of clearance to any combustible materials (like wood framing or drywall).', 'The Fix: This clearance can only be reduced if you wrap the duct in an ICC-ES listed field-applied multi-layer fire barrier blanket system (like 3M Fire Barrier or FireMaster wrap).']
what is the required clearance to combustibles for a type 1 grease duct (black iron)?