Section/elevation view before hanging duct not checked
Check section/elevation views before hanging duct. Plan view can hide height, stacking, and clearance problems.
Stop if
- Is there a section/elevation view that controls this duct height?
Watch out
- Do not hang from plan view only when elevation matters.
Check
- Find the section marker.
- Open the section/elevation view.
- Check duct height relative to steel/ceiling/sprinkler/lights.
- Confirm hanger/support direction.
- Ask if plan and section do not match.
Steps
- Find the section marker.
- Open the section/elevation view.
- Check duct height relative to steel/ceiling/sprinkler/lights.
- Confirm hanger/support direction.
- Ask if plan and section do not match.
Say this to your foreman
Is there a section/elevation view that controls this duct height?
More in Print Reading, Tags & Layout