Measuring from the wrong reference point on the tape (the hook gap error)

Understand that the hook slides by exactly one thickness to self-compensate for inside vs outside measurements. For critical dimensions, use a hard stop rather than the hook.

Sealing, Leakage, Mastic & Pressure Testing 2nd Year YELLOW