Cable tray blocks planned elevation
When cable tray is sitting at the planned duct elevation, stop and verify the latest coordinated elevation before lowering/raising the duct.
Stop if
- Cable tray is at our planned duct elevation. Which trade/elevation controls here?
Watch out
- Do not move duct elevation on your own to dodge cable tray.
Check
- Photo the tray and duct route together.
- Check latest coordination model/drawing if available.
- Compare duct elevation, tray elevation, and ceiling clearance.
- Identify whether access/service space is affected.
- Ask before changing elevation.
Steps
- Photo the tray and duct route together.
- Check latest coordination model/drawing if available.
- Compare duct elevation, tray elevation, and ceiling clearance.
- Identify whether access/service space is affected.
- Ask before changing elevation.
Say this to your foreman
Cable tray is at our planned duct elevation. Which trade/elevation controls here?
More in Coordination, Clashes, Sequencing & Rework